To secure the system, close all doors and windows and cease all motion in areas covered by motion detectors. When this message appears, one or more zones are not secured. The exit delay time can be changed by your installer. You can restart the exit delay once by pressing the  button before the exit delay expires. At the end of the exit delay period, all keypad lights, except the Armed light, will turn OFF and the system will be armed. The panel will provide an exit delay period, indicated by keypad beeps, for you to exit the premises without causing an alarm. Exit the premises through the door indicated by your installer as the Exit/Entry door.

#Dsc alarm reset code#

If the correct access code is entered, the keypad sounder will beep quickly and the Armed light will come ON. If this occurs, press the  key and re-enter your. If the access code was entered incorrectly, the keypad buzzer will sound steadily for one second. As each digit is entered, the keypad sounder will beep. The system cannot be armed unless the Ready light is ON indicating that all zones are closed and the system is in the Ready state.Įnter your. If the Ready light is OFF, check to see that all doors and windows are closed and that motion is stopped in areas covered by motion detectors. If the Ready light is ON, the system is ready for arming. NOTE: The alarm memory is cleared each time the panel is armed so that any alarms showing are alarms that occurred only during the last armed period. Use the arrow () keys to view which troubles are affecting the system. Upon disarming and if a trouble is present, this message will be displayed. If a zone is still in alarm, the display will show the following message to indicate that a zone is open… Secure System Use the arrow () keys to view which zones caused the alarm. If an alarm occurred while the system was armed, this message will be displayed. NOTE:The alarm memory is cleared each time the panel is armed so that any alarms showing are alarms that occurred only during the last armed period. Pressing the  key during the 30 second period will cancel the alarm memory display. After the 30 second period, the Memory (or System) light and zone light will stop flashing and the panel will return to the Ready state. If an alarm occurred while the system was armed, the Memory light (or System light on a PC1555RKZ keypad) and the zone light corresponding to the zone which caused the alarm will flash for 30 seconds.







Dsc alarm reset